Unibrain 980 Bedienerhandbuch Seite 36

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 35
Unibrain Fire-i 52x/620/720/820 Operation Manual Page 30
ON_OFF
[6]
Write: ON or OFF this feature
Read: read a status
0: OFF, 1: ON
If this bit=0, other fields will be read only.
Trigger_Polarity
[7]
If Polarity_Inq is “1”, Write to change polarity of
the trigger input Read to get polarity of trigger
input
If Polarity_Inq is “0”, Read only. (0: Low active
input, 1: High active input)
[8..11] Reserved
Trigger_Mode [12..15] Trigger mode.(Trigger_Mode_0-15)
[16..19] Reserved
Parameter [20..31] Parameter for trigger function, if required.
3.10.2. Trigger Timing Diagram
Correlation of VD and fps
Cameras 60 fps 30 fps 15 fps 7.5 fps 3.75 fps 1.875 fps
IMx-1200
IMx-1140
- - 1 VD 2 VD 4 VD 8 VD
IMx-1080 1 VD 2 VD 4 VD 8 VD 16 VD
IMx-1050
IMx-1040
1 VD 2 VD 4 VD 8 VD 16 VD 32 VD
Cameras 50 fps 25 fps 12.5 fps 6.25 fps 3.125 fps 1.5625 fps
IMx-1070 1 VD 2 VD 4 VD 8 VD 16 VD 32 VD
Seitenansicht 35
1 2 ... 31 32 33 34 35 36 37 38 39 40 41 ... 63 64

Kommentare zu diesen Handbüchern

Keine Kommentare