Unibrain 980 Bedienerhandbuch Seite 35

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 64
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 34
Unibrain Fire-i 52x/620/720/820 Operation Manual Page 29
3.9. Gain
Gain refers to the amount of the CCD output signal amplification where gain and shutter have similar effect to the
image. Manual and Automatic gain mode are supported and manual adjustment is possible for the following range.
For Gain control inquiry and status register, follow the same definition as “BRIGHTNESS.
Camera Type Step Range Range in dB Increment Length
Monochrome Camera 0 ~ 723 0 ~ 25 approx. 0.0345 dB/step
Color Camera 0 ~ 723 0 ~ 25 approx. 0.0319 dB/step
3.10. Trigger & Strobe
The cameras support external trigger by receiving input through the external trigger port The falling edge and rising
edge can be detected as trigger according to the modes it supports as per the following table. Strobe timing is user
controllable while signal output is TTL. A software trigger can also be used which issues trigger signal via software
command.
3.10.1. Supported Trigger
Edge Rising Edge or Falling Edge
Mode 0, 1, 2, 3, 4, 5, 14
Trigger
Source External or Software Trigger
Inquiry Register
Address Name Field Bit Description
Presence_Inq
[0]
Presence of this feature
Abs_Control_Inq
[1]
Capability of control with absolute value
- [2..3] Reserved
ReadOut_Inq [4] Capability of reading the value of this feature
On/Off_Inq [5] Capability of switching this feature On and OFF
Polarity_Inq [6] Capability of changing polarity of trigger input
[7..15] Reserved
Trigger_Mode0_Inq [16] Presence of Trigger Mode0
Trigger_Mode1_Inq [17] Presence of Trigger Mode1
Trigger_Mode2_Inq [18] Presence of Trigger Mode2
Trigger_Mode3_Inq [19] Presence of Trigger Mode3
530h TRIGGER_I
NQ
[20..31] Reserved
Status Control Register
Address Name Field Bit Description
Presence_Inq
0
Presence of this feature
0:N/A 1:Available
Abs_Control
[1]
Absolute value control
0: Control with value in the Value field
1: Control with value in the Absolute value CSR
If this bit = 1, value in the Value field is ignored.
830h TRIGGER_
MODE
- [2..5] Reserved
Seitenansicht 34
1 2 ... 30 31 32 33 34 35 36 37 38 39 40 ... 63 64

Kommentare zu diesen Handbüchern

Keine Kommentare